Page 36 Mealstream 401Ovens 32Z3311 Issue 8
For the oven to operate at peak efficiency, the cavity, door and air filters must be kept clean.
A daily cleaning routine will ensure that you comply with the required hygiene standards and will help
to maintain and prolong the efficiency of your oven.
Follow the SAFETY INSTRUCTIONS at the beginning of this manual.
ALWAYS switch off at the electrical supply and allow oven to cool for at least 20 minutes
before cleaning
As required, remove carousel and wipe out spillages with disposable paper wipes
NEVER use steel wool, knives or harsh abrasives on any part of the oven
As with all electrical appliances, it is wise to have the electrical connections inspected
periodically.
1. Remove the air filter from the rear panel of the oven by
sliding the filter up and out of the slots.
2. Wash in clean, warm soapy water, rinse and pat dry. Slide
back into position through slots.
Cleaning the oven cavity and door
1 Remove trays, racks and the rear baffle plate ( undo the four
wing nuts ), turntable and turntable disc. Clean using non-
caustic oven cleaner.
2. Remove food particles from between the inside edge of the door
and the front of the oven floor using a clean, dry brush.
( Location A )
3. Apply non-caustic oven cleaner to interior surfaces except door
seals. Leave for the recommended time. Wash off using a clean
cloth and plenty of clean, warm water. Dry using a fresh, clean
cloth.
4. Wipe hinges with a clean, damp cloth.
DO NOT apply lubricating oil.
5. Wipe door seals carefully with a clean damp cloth. Examine for
signs of wear or damage.
6. Replace baffle plates and tighten wing nuts.
Cleaning the control panel and exterior surfaces
Wipe down regularly with a damp cloth.
Hints and Tips for stubborn stains in the oven cavity
1. Switch on oven with microwave power only (without heat).
2. Place a container of water (1.5 litres) into the centre of the oven cavity.
3. Set microwave power to 100%.
4. Set timer to 30 minutes and press start button.
At end of steam cycle, wipe out cavity with a clean cloth.
DO NOT USE THE OVEN
WITHOUT A CLEAN AIR
FILTER IN POSITION
APPENDIX 2: Cleaning Procedure