Page 8 Mealstream 401Ovens 32Z3311 Issue 8
The Mealstream EC401 will identify some of the most common problems by flashing an error
message code in the time display window.
Error Message
Possible Cause Service
1
2
Door not fully shut
Possible electrical fault
Close door fully.
Check Microswitch Door Circuit
Check Microswitch Connection to PCB
Check Ribbon Cable
Check Relay PCB & Logic PCB
1
2
3
4
5
No time has been set
Invalid time has been set
Invalid program has been set
Number pad failure
Memory Failure running a
Program
Set a time
Set a valid time
Use call-back to check program
(Menukey: no key downloaded)
Membrane key short circuit
Re-Program Pad,
if fault repeats replace Logic PCB
1
2
Oven not heating up
Possible Heater circuit fault
Check heater fuse
Confirm operation of heater, overheat
stat and heater circuit
1 Oven Cavity overheating Check cavity sensor
Confirm heater relay is operating
1 Oven is not at correct
temperature to start program
Operator Error !!
Allow oven to reach correct
Programmed temperature
1 Magnetron overheating Check that magnetron cooling fan is
working correctly
Check air filters
Check location and air inlet temperature
Note : this will lead to condition shown
below
1
2
Magnetron has overheated
but has now recovered
Internal diagnostic fault
Check that magnetron cooling fan and
turntable are working correctly
Check installation, air inlet temperature
and air filters
1 Oven control area is
overheating
Check air filters.
Check axial fan
Check installation for hot air intake
MenuKey removed before the
download is complete
or the process has been
interrupted
Switch oven off and begin the MenuKey
download again
Error codes and diagnostics
Seitenansicht 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 36 37

Kommentare zu diesen Handbüchern

Keine Kommentare